Working Principle
An air circuit breaker (ACB) operates by automatically interrupting current flow upon detection of overload or short-circuit. Under normal conditions, its main contacts remain closed to allow unobstructed current flow. When sustained overcurrent occurs, the thermal element warps from heat accumulation, triggering the tripping mechanism. In sudden short-circuit events, the solenoid coil produces an instantaneous magnetic force to activate the tripping mechanism. This action rapidly separates the main contacts, generating a strong electric arc that is immediately directed to the arc-extinguishing chamber. There, the arc is split, cooled, and extinguished, safely disconnecting the circuit and preventing system damage.
Product Quality
| The moving and stationary contacts are made of copper, while the moving and stationary points are made of silver alloy, offering advantages such as high-temperature resistance, oxidation resistance, and excellent conductivity | ![]() |
![]() |
![]() |
||
![]() |
|||||
![]() |
![]() |
The incoming and outgoing copper busbars are made of thick standard-grade pure copper material | |
![]() |
|||
| The drawer base adopts the standard thickness of copper busbar, and the clamp that interlocks the drawer base with the circuit breaker body is a copper clamp | ![]() |
![]() |
||
![]() |
![]() |
The controller adopts the technology of SunTech and Kefeng, and the circuit board undergoes a 24-hour aging test | |
![]() |
|||
| The undervoltage release coil is sourced from Jiangsu Guoxing, with the coil winding count meeting the standard | ![]() |
![]() |
|
Management quality
| Material Inspection (Contact Spring Pressure, Detection of Contact Points and Copper Busbar Defects, Cold Soldering) | ![]() |
![]() |
|
![]() |
|||
![]() |
![]() |
Batch trial assembly qualification range (travel, clearance, contact pressure, tripping force) | |
![]() |
|||
| Semifinished Product Inspection (Excess Distance Opening Circuit Resistance, Three-Phase Synchronous Closing Full Inspection, Mechanical Reset Operation 15 Times Full Inspection, Mechanism is Whether there is false closing, the above-mentioned other factories may not perform these tests (instantaneous, delayed, short-circuit debugging) | ![]() |
![]() |
|
![]() |
|||
![]() |
![]() |
Finished Product Inspection (5 operations of closing and opening, energy storage, undervoltage tripping, and power-on tests for incoming and outgoing lines in the closed state) | |
![]() |
|||
| The undervoltage release coil is sourced from Jiangsu Guoxing, with the coil winding count meeting the standard | ![]() |
![]() |
|
- Various models, specifications, and sizes can be customized. Our production current ranges from 630A to 6300A and can be customized.
- genuine source factories with high cost-effectiveness
- Equipped with professional debugging equipment and inspection personnel, each product is fully tested with a 2-year warranty. The company has over ten years of production experience, not only producing circuit breakers, but also complete sets of switchgear and using circuit breakers. Various problems encountered in product application have been experienced, and many problems can be avoided. There are professional senior engineers, and the boss has a technical background at Chint. They are professional engineers
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
|
![]() |
![]() |
To ensure transportation safety, our electrical products are exported in reinforced wooden crates. The crates undergo heat treatment and bear the ISPM-15 mark, enabling swift customs clearance. The raised base design facilitates forklift operation, while internal shock-absorbing fastening ensures the products arrive intact. All exterior crates are clearly labeled and comply with international logistics standards.
-
Photovoltaic Grid-Connected Cabinet Utilising ACB and MCCB
-
Power transmission successful
-
Application Scenario Footage
-
Box-typesubstation ACB VCB MCCB
-
Box-typesubstation ACB VCB MCCB
-
Box-typesubstation ACB VCB MCCB
-
Box-typesubstation ACB VCB MCCB
-
Power transmission successful
-
Power transmission successful
-
Photovoltaic Grid-Connected Cabinet Utilising ACB and MCCB
-
Photovoltaic Grid-Connected Cabinet Utilising ACB and MCCB

| Current | 630A-6300A |
| Number of pole | 3P / 4P |
| Breaking Capacity | N1,N2,H1,H1B,H2,H3,L1 |
| Type | Fixed / Drawer |
| Model | MTMT/MTNW/MTMVS |

| On-site M Circuit Breaker Type | MTMT | MTNW | ||||
| MTN1 | MTH1 | MTH2 | MTN1 | MTH1 | MTH2 | |
| M08 3P/4P | √ | √ | √ | √ | √ | √ |
| M10 3P/4P | √ | √ | √ | √ | √ | √ |
| M12 3P/4P | √ | √ | √ | √ | √ | √ |
| M16 3P/4P | √ | √ | √ | √ | √ | √ |
| M20 3P/4P | √ | √ | √ | √ | √ | √ |
| M25 3P/4P | √ | √ | √ | √ | √ | √ |
| M32 3P/4P | √ | √ | √ | |||
| Model NO. | MT12N1 |
| Arc-extinguishing Medium | Air |
| Structure | ACB |
| Type | Circuit Breaker |
| Certification | ISO9001-2000, CE, CCC |
| Single Gross Weight | 25.000kg |
| Material | High Standard Plastic Silver Copper |
| Rated Frequency (Hz) | 50/60 |
| Protection | IP30 |
| Style | Fixed Type |
| Transport Package | Wooden Box |
| Trademark | MINGTUO |
| HS Code | 8536200000 |
| Speed | High-Speed Circuit Breaker |
| Installation | Fixed |
| Poles Number | 3or4 |
| Function | Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection) |
| Selling Units | Single Item |
| Single Package Size | 27X32X40 Cm |
| Rated Voltage | AC400V |
| Productname | Acb Air Circuit Breaker |
| Pole | 3p/4p |
| Certificate | IEC CE CCC |
| Specification | customized |
| Origin | Zhejiang, China |
| Production Capacity | 300 |
| Package Size | 27.00cm * 32.00cm * 40.00cm |
| Package Gross Weight | 26.000kg |